Θερμόμετρο IR / Type-K PeakTech 4950
Προβολή
Innovative and efficient infrared-thermometer that allows non-contact measurements of surface temperatures.
The target can be marked easily with the help of the laser beam; therefore it is possible to make measurements from a safe distance, even in difficult or moving objects.
Moreover, an additional input for K-type temperature sensor for direct contact measurements of surfaces and differential temperature measurements is provided.
LCD-display with backlight, which also permits reading in low light levels
Adjustable emissivity 0,1...1,0
Auto-hold, Auto power off
Switch over function of single or duration measurments
MIN, MAX, DIF, AVG-record
High/low alarm function with audible warning signal of high and low values, chosen freely adjustable over the complete measuring range
Internal memory for up to 20 values
Safety: EN 60825-1
Accessories: Case, K-Type-thermocouple probe,
9 V-battery and manual
Measuring range (IR): -50 ... + 850°C (-58 ...+ 1562 °F)
IR-Accuracy: +/- 1,5% + 2°C / 3,6 °F
Measuring Range (Type K): -50°C + 1370°C (-58 ...+ 2498 °F)
Type-K-Accuracy: +/- 1,5% + 3°C / 5,4 °F
Response time: 150 ms
Resolution: 0,1°C / 0,1 ° F
Optical resolution: 30 : 1
Emissivity: 0,1 ~ 1,0 adjustable
Laser Class: 2 ~ Output: < 1 mW (630 - 670 nm)
Operation voltage; 9 V-Battery
Dimensions (WxHxD): 47 x 180 x 100 mm
Weight: 290 g
The target can be marked easily with the help of the laser beam; therefore it is possible to make measurements from a safe distance, even in difficult or moving objects.
Moreover, an additional input for K-type temperature sensor for direct contact measurements of surfaces and differential temperature measurements is provided.
LCD-display with backlight, which also permits reading in low light levels
Adjustable emissivity 0,1...1,0
Auto-hold, Auto power off
Switch over function of single or duration measurments
MIN, MAX, DIF, AVG-record
High/low alarm function with audible warning signal of high and low values, chosen freely adjustable over the complete measuring range
Internal memory for up to 20 values
Safety: EN 60825-1
Accessories: Case, K-Type-thermocouple probe,
9 V-battery and manual
Measuring range (IR): -50 ... + 850°C (-58 ...+ 1562 °F)
IR-Accuracy: +/- 1,5% + 2°C / 3,6 °F
Measuring Range (Type K): -50°C + 1370°C (-58 ...+ 2498 °F)
Type-K-Accuracy: +/- 1,5% + 3°C / 5,4 °F
Response time: 150 ms
Resolution: 0,1°C / 0,1 ° F
Optical resolution: 30 : 1
Emissivity: 0,1 ~ 1,0 adjustable
Laser Class: 2 ~ Output: < 1 mW (630 - 670 nm)
Operation voltage; 9 V-Battery
Dimensions (WxHxD): 47 x 180 x 100 mm
Weight: 290 g